• ademco lynx 5000 manual

    ademco lynx 5000 manual

    Download Link: ➡ ademco lynx 5000 manual



    File Name: ademco lynx 5000 manual.pdf
    Size: 3529 KB
    Type: PDF, ePub, eBook
    Category: Book
    Uploaded: 26 May 2019, 17:58 PM
    Rating: 4.6/5 from 572 votes.


    Last checked: 14 Minutes ago!









    ⬆ LINK ⬆




















    In order to read or download ademco lynx 5000 manual ebook, you need to create a FREE account.

    eBook includes PDF, ePub and Kindle version



    ✔ Register a free 1 month Trial Account.
    ✔ Download as many books as you like (Personal use)
    ✔ Cancel the membership at any time if not satisfied.
    ✔ Join Over 80000 Happy Readers


    Book Descriptions:

    ademco lynx 5000 manual

    Attach the front and back cases by connecting the hooks on the front case to the attachments on the back case. Once attached, the hooks will support the front case and allow you to make the wiring connections. 6. After all wiring connections have been made, snap the front case and back case closed and ensure that the case is secured by the locking tabs.Refer to the Wiring Connections paragraph and the Summary of Connections diagram on the inside back cover when making connections.The following are examples of good earth grounds available at most installations:AC Power Outlet Ground - Available from 3-prong, 120VAC power outlets only. To test the integrity of the ground terminal, use a three-wire circuit tester with neon lamp indicators, such as the UL Listed Ideal Model 61-035, or equivalent, available at most electrical supply stores. a. Connect terminal EGND to a good earth ground as shown on the Summary of Connections. 2. Make Phone Line Connections - For local or full line seizure follow the appropriate steps below.Plugging the Direct Connect Cord directly into the RJ31X jack, allows the control to seize the phone line when an alarm occurs and normal phone line usage by the premises phones if the plug needs to be removed. c. Cut the incoming RING and TIP phone lines (typically red and green, respectively) and connect them to RJ31X terminals 4 (red) and 5 (green). d. Connect the premises end of the cut RING and TIP wires to RJ31X terminals 1 (grey) and 8 (brown) respectively. e. Wire the flying leads of a Direct Connect Cord to the control's phone terminals as shown in the diagram or plug into the 8-position jack. f. Plug the Direct Connect Cord into the RJ31X jack. HARDWIRED ZONE: If the EOLR is not at the end of the loop, the zone will not be properly supervised, and the system may not respond to an open circuit on the zone. 3.

    • ademco lynx 5000 manual, honeywell lynx 5000 manual, honeywell lynx 5000 programming manual, honeywell lynx 5000 user manual, ademco lynx 5000 manual download, ademco lynx 5000 manual pdf, ademco lynx 5000 manual instructions, ademco lynx 5000 manual user, ademco lynx 3000 manual, ademco lynx 5000 manual, honeywell lynx 5000 manual, honeywell lynx 5000 programming manual, honeywell lynx 5000 user manual, ademco lynx 5000 manual, ademco lynx 5000 manual download, ademco lynx 5000 manual pdf, ademco lynx 5000 manual instructions, ademco lynx 5000 manual user, ademco lynx 3000 manual.

    Product availability, at the moment, is in flux. If you order today, depending on the product, there may be a significant delay in shipping it to you. We apologize for any delays, and assure you that products will be shipped as soon as we can get them. Before COVID, we had significant stock of nearly every popular product that we sell. But demand has outpaced our supplier's ability to meet it, and has exhausted the stock we had purchased to meet increased demand during the government-mandated lockdowns. If you need the product right away, it is unlikely we will be able to accommodate you. For that we apologize. We ask for your patience as we all navigate this unique situation together. Be nice to our employees, they are doing their best to answer your questions and get your product to you as quickly as they can.If you are here to get product quickly because you are unable to get the product at your usual supplier, rest assured, we are also out of the product and won't be able to fulfill your order in a timely manner. Like our end-users, we will be delivering products as soon as we get them in. For the purpose of improving our site, we’d like to know if you are one of the following: Smoke could be blocked by the closed door. If detectors are not so located, a fire within the room could prevent the control from reporting a fire or an intrusion. This will ensure that alarm signals can be sent to the alarm monitoring station in the event that the telephone lines are out of order (alarm signals are normally sent over the phone lines, if connected to an alarm monitoring station). -2- Rear Cover A built-in speaker provides voice annunciation of system status along with voice descriptors of each zone. An internal module (if provided) allows the LYNX Touch to communicate with the Central Station via the Internet or GSM Cellular Wireless. Use tie-wraps to secure the wiring to the built-in wire loops as needed. 4. Mount the back case to a sturdy wall. 5.

    After the wiring connection has been made, snap the front and the back case closed. 11. Plug the power supply into a 24-hour, 110VAC unswitched outlet.Rechargeable batteries may take up to 48-hours to fully charge.This allows site maintenance independent of central station monitoring, and modification to sites globally via the Internet or through a private LAN.Ensure that the connector board is properly seated into the receptacle on the control. Secure the GSMVLP5 with the three provided screws. Enable the GSMVLP5 device, configure alarm reporting and module supervision and register the device. Refer to the “Program the Communications Module” and “Communications Diagnostics” sections. Remove the ILP5 receptacle knockout from the left side of the LYNX Touch back case. Install the ILP5 into the LYNX Touch control front case. Ensure that the connector board is properly seated into the receptacle on the control. Secure the ILP5 with the three provided screws. Insert the ILP5 receptacle and spacer into the slot on the back case. Secure the communications cable to the tie wrap point on the ILP5 with the provided tie wrap. Connect the Ethernet cable to the RJ45 receptacle. Enable the ILP5 and configure alarm reporting and module supervision and register the device. Refer to the “Program the Communications Module” and “Communications Diagnostics” sections. Ensure that the connector board is properly seated into the receptacle on the control. Insert the ILP5 receptacle into the slot on the back case as shown on the figure below. Refer to the “Program the Communications Module” and “Communications “Diagnostics” sections. Range The built-in RF receiver can detect signals from wireless transmitters within a nominal range of 200 feet. Transmitters 5800 Series transmitters have built-in serial numbers that must be entered into the system using the “Zones” programming section, or input to the control via the downloader.

    Hardwired Zone Connections - One EOLR supervised zone supports both open circuit and closed circuit devices and has a response time of 350msec. The EOL resistor must be connected in series with the devices, following the last device. c. Connect open circuit devices in parallel across the loop. The 2000-ohm EOLR must be connected across the loop at the last device. 4. AC Power Connections - Connect the Power Supply to the receptacle on the LYNX Touch.Connect four wires between the L5000-RJ31X receptacle terminal strip and the incoming phone line and the premises telephones as shown on the figure below. Install the L5000-RJ31X receptacle into the slot on the back case. Connect one end of the L5000-RJ31X cable to the 8-position jack on the LYNX Touch PC board. Route the cable through the opening in the back case and along the wire channel in the back case. Connect the other end of the cable to the L5000-RJ31X receptacle on the side of the back case as shown below. Secure the wires to the tie wrap points on LYNX Touch front and back case with the provided tie wraps. Ensure enough slack is left in the wires to allow the case to close without pinching the wires. Refer to the wiring table below for wire gauge and length. In the event of an AC power loss, the system is supported by a long life backup battery that is supervised for connection and for low voltage conditions. If the battery is missing, or a low battery condition is detected, a “low battery” message is displayed and a report is sent to the central station. In addition, the system will beep once every 45 seconds to audibly indicate a low battery condition (press any key to stop the beeping).Do not plug the power supply into the AC outlet until after all wiring connections have been made. Ensure the cover is snapped closed prior to applying AC power Secure battery wiring in the wire routing clips (3). 9. Connect the battery connector to the receptacle on the PC board. 10.

    The system displays all programmed zone numbers and zone descriptors, which have a non-zero Zone Type. Fault each transmitter in turn, causing each one to send a signal. As the system receives a signal from each of the transmitters, the zone number of that transmitter disappears from the display. The transmitters may be checked upon installation, or in an installed system. The system will beep once every 30-40 seconds while the RF Sniffer Test mode is active. 4. When all transmitters have been checked, Exit RF Sniffer Test mode by depressing the Off key and entering the Installer or a User Code. When one button of a button type, supervised or unsupervised RF transmitter (RF, UR, or BR) is activated, all zones assigned to other buttons on that transmitter are cleared. This also applies to 5816 and 5817 transmitters that have multiple loops (zones). Any transmitter that is not “entered” will not turn off its zone number.This mode is similar to the transmitter Test mode, except that the wireless receiver gain is reduced. This will enable you to make sure that the RF signal from each transmitter is received with sufficient signal amplitude when the system is in the normal operating mode.The following options are displayed. Walk Test RF Sniffer Test Go-No-Go Test Dialer Test Select “Go-No-Go Test”. Once you have placed transmitters in their desired locations, and the approximate length of wire to be run to sensors is connected to the transmitter's screw terminals (if used), fault each transmitter. a. The keypad beeps three times indicating signal reception, displays the appropriate zone number and announced the zone description. b. If the keypad does not beep, reorient or move the transmitter to another location. Usually a few inches in either direction is all that is required. If each transmitter produces the proper keypad response when faulted, they can be permanently mounted according to their respective instructions.

    5800 Series transmitters (except the 5800RL) do not have DIP switches. Each transmitter's zone number is also programmed into the system in the “Zones” programming section. On the 5816, for example, the wire connection terminal block is loop 1; the reed contact is loop 2. Each loop must be assigned a different zone number. Each button on the transmitter also has a pre-designated loop or input number, which is automatically displayed. House ID 00 disables all wireless keypads. An RF House ID is not necessary for other 5800 Series transmitters; the entry should be left at “00” (default) in those cases. Transmitter Input Types Each of the transmitters has one or more unique factory-assigned input (loop) ID codes. Each of the inputs requires a programming zone (e.g., a 5804's four inputs require four button zones). Transmitters can be entered as one of the following types (see transmitter’s instructions for appropriate input type). The transmitter must remain within the receiver's range. The transmitter may therefore be carried off-premises. Sends only fault signals. They do not send low battery signals until they are activated. The transmitter may be carried off-premises. Factors such as humidity, high or low temperatures, as well as large swings in temperature may all reduce the actual battery life in a given installation. The 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, and 5804E button transmitters have replaceable batteries.Sniffer mode does not automatically expire. You must manually exit Sniffer mode by selecting Off and entering the Installer Code to return to normal operation.The following options are displayed. Walk Test RF Sniffer Test Go-No-Go Test Dialer Test 2. Select “RF Sniffer Test” from the options. Note: If the communicator is in the process of sending a report to the central station, the system will not go into the Sniffer mode. If so, wait a few minutes and try again. 3.

    ” key as required until system displays a Confirmation screen.If “No” is selected, you can still re-enter Program Mode by powering down the unit (remove AC and battery power) and entering Program Mode within 30 seconds of powering up. 4. Select the “!” key again to return to the Home Screen. Zone types are defined below.Exit delay is independently programmable. Exit and entry delays when armed in AWAY or STAY mode. No entry delay when armed in STAY INSTANT or AWAY INSTANT mode. Exit delay regardless of the arming mode selected. Exit delay is independently programmable. Secondary entry delay, if armed in the AWAY or STAY mode. No entry delay when armed in the STAY INSTANT or AWAY INSTANT mode. Exit delay begins regardless of the arming mode selected. Instant alarm, when armed in AWAY, STAY, STAY NO DELAY, or AWAY INSTANT mode. Instant alarm in all other situations. Active when armed in AWAY or AWAY INSTANT mode. Bypassed automatically when armed in STAY or STAY INSTANT mode. Usually assigned to a zone that covers a sensitive area (i.e.: stock room, drug supply room, etc.) It can also be used on a sensor or contact in an area where immediate notification of an entry is desired. Usually assigned to a zone containing an Emergency button (silent emergency). Usually assigned to a zone containing a button for use in personal emergencies or to a zone containing monitoring devices (i.e.: water or temperature sensors, etc.). Can be assigned to any wireless zone used as a fire zone. This zone type is always active and cannot be bypassed. Bypassed when the panel is armed in the STAY or STAY INSTANT mode. This zone type is always active and cannot be bypassed. Fire with verification is available with smoke detector device type. This zone type is always active and cannot be bypassed. If the zone remains faulted after 30 seconds a fire alarm is provided. If any other fire zone is faulted during the 30 second delay window a fire alarm is immediately provided for that zone.

    An alarm for original fire zone will also be provided if that zone is still faulted afterward. If there are no fire alarms after the 30 second delay expires, the system will open a 60 second window. No keypad sounding or chime System can still be armed No display on the screen Instant alarm, with NO audible indication when is armed in the AWAY, STAY, STAY NO DELAY, or AWAY INSTANT mode. Report sent to the central station. No reports to the central station. Monitors entry into a monitored area. Activates a one-time unique chime sound and announcement when faulted. Activity Zone No. and Zone Descriptor displayed on LCD. Restore will be stored in event log. Activates a unique chime sound and zone announcement when faulted. System re-triggers audible sounding every ten seconds until acknowledged (Off sequence or wireless key button). If programmed, triggers a voice message (follow me) report. If triggered by a PIR, the system remains latched until another Monitor or Response zone has been tripped or a specified time interval has elapsed. System re-triggers audible sounding every ten seconds until acknowledged (Off sequence or wireless key button).Special-purpose zone type used with 5800 Series wireless pushbutton units. Special-purpose zone type used with 5800 Series wireless pushbutton units. Assigned when no-alarm response is required Assigned sensors or contacts on doors and windows or asset protection within the premises. Used to track activity of the occupant and alert occupant of the activity of others. Used to track activity of the occupant and alert occupant of the activity of others. Requires acknowledgement by caregiver. Diagnostics ReporterSystem Settings Reset Master Code Wait for system to terminate the system initialization delay. 2. Depress the OFF key again. The touchscreen displays a keypad. 3. Press the “Clear” key. A blue vertical bar is displayed below the “Enter Code”. 4. Enter “00” on the keypad.

    The system will beep once every 30-40 seconds while the Go-No-Go Test mode is active. Exit Go-No-Go Test mode by depressing the Off key and entering the Installer or a User Code. - 13 - Supervised RF (RF) devices send periodic check-in signals, faults, restore and low battery signals. Unsupervised RF (UR) devices send periodic check-in signals, faults, restore and low battery signals but the control does not supervise the check-in signals. (3) If an external sounder is required, the 5800WAVE should be used. The screen displays status icons and associated text, the current time, system status information and menu choices. The Menu area includes a list of commands, or choices that apply to the current selection. The status area provides information about various system events and a colored bar also provides an indication of system status. A “Home Screen” is displayed whenever power is applied to the system. In addition the green “READY” LED is lit when the system is ready or flashes when it is not.Once activated, the control will take you to the next screen. Selecting the “Home” (cancel) key or the “!” Key will return you to the previous screen at any time unless System Programming mode is active. By Touching (selecting) an icon or key the system, depending on the function, advances to another screen, toggles between options or scrolls through multiple options that can be selected. The system provides a prompt when a specific input is required.This will allow you to clearly hear the feedback announcements or system beeps from the system’s built-in speaker. To adjust the volume, select “More” on the “home Screen” and then select “Settings”. Adjust the volume using the slide displayed on the Settings screen and then select “Save” to accept. Upon exiting the Program Mode, the system resets the volume to the default value (mid level). The time and date are displayed at the bottom of the Home Screen. The Home Screen consists of two pages.

    The first page displays the system status and eight selection “buttons” and “tabs”. Provides information about system status Used to Arm the system in Away mode (displayed on both Home Screen pages). Used to Arm the system in Stay mode (displayed on both Home Screen pages). Provides access to Message Center. Provides access to Speaker Phone mode. (if programmed) Used to toggle between exit delay and instant arming options (displayed on Home Screen pages). Advances system to second page of the Home Screen. - 15 - Used to Arm the system in Away mode (displayed on both Home Screen pages). Used to toggle between exit delay and instant arming options (displayed on both Home Screen pages). Returns system to first page of the Home Screen. Entering the Installer Code is required to access the Installer Menu. Note: For information regarding the Devices, Events and Schedules programming screens, refer to the User Manual.Entering the Master User Code is required to access the User Menu.The system can be programmed at any time, even at the installer's premises prior to the actual installation. Simply apply power temporarily to the Control and then program the unit as desired. The “Initiate Download” button is used to initiate remote programming using an IBM PC compatible Personal Computer, and Compass Downloader and modem or via capable GSM or IP communications modules.The system must first be disarmed. Select “Tools”. The touchscreen displays a keypad. Enter the Installer Code 4112. The System Programming Screen is displayed. Select “Program” to display the following options: Diagnostics Reporter System Settings Reset Master Code Refer to the Programming Default Tables section of thisIf a default table is loaded, any data that has already been programmed into the system will be changed according to the default table selected! System Settings Reset Master Code The system returns to the previous screen. 2. Select the “!

    The system will enter Installer Programming mode and the Installer Tools Menu will be displayed. Enter a new four-digit Installer Code on the displayed keypad The system will display the new code on the left side of the screen. Select “Done” when you are finished. The system returns to the “System Programming” Screen. ACTION 2. 3. 4. The System toggles between the following: Disabled Enabled 4. Select “Two-Way Voice”.The System toggles between the following: Disabled Enabled 5. Select “RF House Code”. 6. After entering a code (00-31) on the displayed keypad, select “Done”. 7. Select “Phone Notification” (phone line cut). The System scrolls between the following options: Disabled Keypad Trouble If “Keypad” or “Trouble is selected proceed to Step 8. 8. If Keypad or Trouble was selected in Step 7, the “Phone Detect Time” option is displayed. Select “Phone Detect Time”. The system scrolls between the following options: 1 Minute 2 Minutes 3 Minutes 4 Minutes - 21 - The system displays “Press To Log All”. Selecting this option programs the system to log all events and “Log All Set” is displayed. Additionally all of the options listed below are enabled. The System toggles between “Enabled” and “Disabled”. Remote Access Serial Disabled Non Security Disabled Multi Mode Serial Disabled 17. Select “Multi Mode Serial”. The System toggles between “Enhanced Reports” and “Disabled”. 18. Select “Save” when complete. 15. Select “Remote Access Serial”. If the Remote Access Serial” option is enabled, the “Multi Mode Serial” option is displayed. 16. Select “Non Security”. The System toggles between “Enabled” and “Disabled”. SCREEN ACTION Note: If you are installing a GSMVLP5 or ILP5 Communication Module, the time and date will be programmed and updated automatically via Central Station. You must still program the correct Time Zone below. 1. Select “Date Time”. 2.Enter the correct time and then select AM or PM.The system toggles between “Yes” and “No”.

    If “Yes” is selected the following options will become active. 7. Select “Start Month”. The system displays the following options. September October November December 8. Select “Start Week”. The system scrolls between the following options. First Fourth 3rd from Last Second Last Third Next to Last 9. Select “End Month”. The system displays the following options. September October November December 10. Select “End Week”. The system will scrolls through the available weeks. First Fourth 3rd from Last Second Last Third Next to Last 11. After programming these options, select the “Save” key. - 23 - IP or GSM Multi Mode IP or GSM IP Fault Time Use DHCP NIC IP Address Subnet Mask Gateway IP Address DNS Server IP Address GSM Fault Time GSM Rollover GSM 24 Hour Test Selects how long an undeliverable alarm delivery is retried to the Central Station. Dynamically selects the IP addresses (Appears only if “No” is selected in Use DHCP field.) Enter NIC IP Address. (Appears only if “No” is selected in Use DHCP field.) Enter Subnet Address. (Appears only if “No” is selected in Use DHCP field.) Enter Gateway IP Address (Appears only if “No” is selected in Use DHCP field.) Enter Domain Name Server IP Address. (Appears only if GSM is enabled in Communications Path field.) Selects time delay before the Communications Module notifies the control panel of a loss of contact with the network. Allows messages to be sent over GSM in the event that contact with the internet is lost. Enables daily test of GSM module operation. Remote Access (Total Connect) and Multi Mode (PSD) over IP or GSM cannot be enabled in the panel alone. Availability of this service is controlled via the web-based programming tool on the AlarmNet Direct website. These features must to be enabled through the AlarmNet Direct website first and transferred to the device. SCREEN ACTION Communicator 1.

    Select “Communicator” The System displays the following options: Communications Path APL City ID CS ID Sub ID Supervision Old Alarm Time Remote Acc. GSM Fault Time OR IP Fault Time 2. Select “Communications Path”. The system scrolls between the following options: None IP GSM Select “APL”. The system scrolls between “Enable” and “Disable”. Options 01-99 Select “CS ID”. Enter the 2-digit Primary Central Station ID (HEX). Options 01-FE - 24 - Enter the 4-digit Subscriber Account Number (Decimal). Options 0001-9999 Select “Supervision”. The system scrolls between the following options: 24 Hours None 30 Days Select “Old Alarm Time”.The system scrolls between the following options. Disabled Relay Reports Enhanced Reports 11. If IP was selected in step 2, proceed to step 12. If GSM was selected in step 2, proceed to step 19. 12. Select “IP Fault Time (min)”. Enter the time delay (in minutes) on the displayed keypad. Options 00-99 13. Select “Use DHCP”. The system toggles between “Yes” and “No”. If “No” is selected the system displays four additional options. If “Yes” is selected, skip to step 18. 14. Select “NIC IP Address”. Enter the 4-part address on the displayed keypad. Enter the 4-part address on the displayed keypad. Enter the 4-part address on the displayed keypad. Enter the 4-part address on the displayed keypad. 18. If “IP” was selected in step 2, select “Save” and then select “OK” when the “Programming Done” screen appears. Proceed to “Diagnostics” section in order to register the device. 19. Select “GSM Fault Time (min)”. Options 00-99 20. If “GSM” was selected in step 2, select “Save” and then select “OK” when the “Programming Done” screen appears. Proceed to “Diagnostics” section in order to register the device. The following options are displayed (dependant upon Zone Type): Serial Number Loop Number Zone Description 1 Zone Description 2 Device Type Response Type Alarm Report Chime Supervision 4. Select an option to display the next programming field.

    Serial Number When “Serial Number” has been selected “Enter Serial Number or Activate” is displayed. The transmitter serial number and loop number can be enrolled via RF transmission OR manually. The initial transmission activates the RF Learning mode and the system will emit a single beep. A second transmission enrolls the serial number and the system beeps two times and displays “Activate Sensor Again To Confirm”. A third transmission will confirm the serial number. The system beeps two times and returns to the Zone programming Screen. Enroll Manually Enter the 7-digit serial number printed on the transmitter using the displayed keypad and select “Done”. The system beeps one time and returns to the Zone programming Screen. For a list of the pre-programmed Zone Descriptors, please visit Select “Zone Description 1 or Zone Description 2”. Using the displayed keypad enter Zone Description 1 or Zone Description 2. The system announces the Zone Description. Enter “Done”, when you are finished. The system returns to the Zone Programming page. - 26 - Use the % arrow to return to the previous page. 24 Hour Auxiliary Fire No Verification Interior With Delay Monitor Carbon Monoxide Trouble Arm Stay Arm Away Disarm No Response Silent Burglary Resident Monitor Resident Response General Monitor General Response Fire With Verification 3. Select Response Type and select “Save”. The system will return to the Zone screen Alarm Report Yes Alarm Report Note: This field is for Alarms. If Response Type “Trouble” is set up and Alarm Report is set to “No” the system will still report if Report Alarms was enabled in the Reporter programming. Select “Report” to toggle between “No” or “Yes”. Select “Chime” to toggle between “No” or “Yes”.Note: If applicable, preprogrammed defaults for the LYNX Touch Control are shown on the screen unless otherwise noted. Key Type Select “Key Type”. The system displays options for User 8 through 14.

    Refer to the LYNX Touch User Guide for additional Information regarding User Codes. Serial Number 0 Serial Number When “Serial Number” has been selected “Enter Serial Number or Activate” is displayed. The initial transmission activates the RF Learning mode. The system beeps three times and returns to the Zone programming Screen. Zone 49 Zone The system displays the next available key Zone number. Select “Zone” to manually enter a specific Zone Number on the displayed keypad (49-64). If the desired Zone Number is not available, the system returns to the previous screen. Select ”Done”. The system returns to the previous screen. Repeat the previous step to enter another Zone Number. - 28 - The system displays the following options: Disarm Arm Away Arm Stay No Response 24 Hour Silent 24 Hour Audible 24 Hour Auxiliary Silent Burglary Fire No VerificationSelect the Report Format that will be used to send reports to the Primary or Secondary Central Station, as applicable. Enter the Phone Number for the Primary or Secondary Central Station, as applicable. Select the type of Communications Module that will be used to communicate with the Primary or Secondary Central Station, as applicable. Enter the account number for the Primary or Secondary Central Station, as applicable. Select the primary method for sending Reports to the Primary or Secondary Central Station, as applicable. Selects delay between switching between reporting methods. Active if Dynamic Delay feature has been set to Preferred Telco or Preferred Radio. Enable All Reports to be sent to the Primary or Secondary Central Station, as applicable. Enable Alarm Reporting to the Primary or Secondary Central Station, as applicable. Enable Trouble Reporting to the Primary or Secondary Central Station, as applicable. Enable Test Reporting to the Primary or Secondary Central Station, as applicable. Enter Number for Follow Me Phone 1 or Phone 2, as applicable.


  • Commentaires

    Aucun commentaire pour le moment

    Suivre le flux RSS des commentaires


    Ajouter un commentaire

    Nom / Pseudo :

    E-mail (facultatif) :

    Site Web (facultatif) :

    Commentaire :